Products and services. Alcan Cable New goods. New services. Alcan Cable http://10008.us.all.biz Sun, 26 Feb 2012 11:40:26 +0200 http://www.all.biz/img/logo.gif ALL.BIZ: USA. http://10008.us.all.biz Transmission, Aluminum Alloy, 6201 http://www.us.all.biz/g187/ B230, Specification for Aluminum 1350-H19 Wire for Electrical Purposes. B398, Specification for Aluminum Alloy 6201-T81 Wire for Electrical Purposes. B524, Specification for Concentric-Lay-Stranded Aluminum Conductors, Aluminum Alloy Reinforced (ACAR), 1350/6201).]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g187/ Conductor AAAC, All Aluminum Alloy, 6201 http://www.us.all.biz/g189/ B398, Specification for Aluminum Alloy 6201-T81 Wire for Electrical Purposes B399, Specification for Concentric-Lay-Stranded Aluminum Alloy 6201-T81 Conductors. All aluminum alloy (6201-T81) conductors are used in both distribution and transmission applications where higher strength is required. Alcan 6201-T81 conductors provide good resistance. Conductors are sized to the equal ACSR diameter are available in sizes 30.58kcmil throuhg 92402 kcmil.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g189/ Conductor AAC, All Aluminum http://www.us.all.biz/g191/ B230, Specification for Aluminum 1350-H19 Wire for Electrical Purposes. B231, Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g191/ Conductor, All Aluminum Alloy, Reinforced ACAR http://www.us.all.biz/g193/ B230, Specification for Aluminum 1350-H19 Wire for Electrical Purposes. B398, Specification for Aluminum Alloy 6201-T81 Wire for Electrical Purposes. B524, Specification for Concentric-Lay-Stranded Aluminum Conductors, Aluminum Alloy Reinforced (ACAR), 1350/6201).]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g193/ Conductor, Aluminum Steel Reinforced ACSR http://www.us.all.biz/g195/ B230, Specification for Aluminum 1350-H19 Wire for Electrical Purposes. B232, Specification for Concentric-Lay Stranded Aluminum Conductors, Coated Steel Reinforced (ACSR). B498, Specification for Zinc-Coated (Galvanized) Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g195/ Conductor, HiTemp EC™ Aluminum Steel Supported ACSS, ACSS/TW http://www.us.all.biz/g197/ Alcan Cable now offers a new family of premium aluminum transmission cable products to the Utility market, Aluminum Conductor Steel Supported (ACSS) and Aluminum Conductor Steel Supported/Trapezoidal Wire (ACSS/TW). Promoted as "The High Temperature, Low Sag Solution", the new line of Alcan conductors have the advantage of operating continuously at high temperatures up to 250 o C (482 o F) with reduced sag in transmission lines and the capability of transporting between 50 to 70% more current than conventional transmission cable products. Both ACSS and ACSS/TW conductors are composite concentric-lay-stranded products consisting of steel central cores that are multi-layered with 1350-0 aluminum wire. Plus, ACSS/TW conductors contain up to 25% more aluminum in the same diameter as conventional ACSR cable resulting in increased ampacity.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g197/ Conductor, Compact AluminumTrapezoid Wire Steel Reinforced ACSR/TW http://www.us.all.biz/g199/ Alcan Cable is always working to find new ways to help electric utilities transfer more revenue-producing energy to the consumer by reducing line losses. As part of this effort, Alcan has developed Compact/TW Conductor. Because of its higher efficiency, over 2,700 conductor miles of Alcan Compact/TW are already in service in North America. The Shape's The Key To Improved Performance.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g199/ Cable, Secondary Multiplex Overhead http://www.us.all.biz/g201/ Alcan Multiplexed Overhead Service and Secondary Cable assemblies consist of one or more insulated conductors and one bare neutral conductor. The cable assembly may be used as a service drop (power pole to service entrance) or as a secondary cable (pole to pole). XLPE insulated cables are rated for 90° C operation, and PE are rated for 75° C.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g201/ Cable, Underground Service 600V http://www.us.all.biz/g203/ Alcan underground 600 volt cables are designed for use in electric distribution circuits not exceeding 600 volts phase to phase. These cables are available as single conductor or with one, two or three phase conductors and a neutral twisted together with no overall cover. The neutral is equal in size to, or two sizes smaller than, the phase conductors. These cables may be directly buried or installed in ducts. They may be used in wet or dry locations at conductor temperatures not exceeding 90°C for normal operation, 130°C for emergency overloads and 250°C under short circuit conditions.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g203/ Cable, Two Layer Ruggedized, ALGUARD 600 Volt 75C http://www.us.all.biz/g205/ Alcan 75° C two layer ruggedized cable is designed for use in underground circuits where superior protection from mechanical abuse is required and the circuit voltage does not exceed 600 volts phase to phase. These cables may be directly buried or installed in ducts. They may be used in wet or dry locations and at conductor temperatures not exceeding 75°C for normal operation, 95°C emergency overloads and 150°C for short circuit conditions.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g205/ Cable, Single Layer Ruggedized, ALHIDE® 600 Volt 90C http://www.us.all.biz/g207/ Alcan single layer Alhide® is designed for use in underground circuits where superior protection from mechanical abuse is required and the circuit voltage does not exceed 600 volts phase to phase. These cables may be directly buried or installed in ducts. They may be used in wet or dry locations at conductor temperatures not exceeding 90° C for normal operations, 130° C emergency overloads and 250° C for short circuit conditions.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g207/ Cable, STABILOY® Service Entrance, Type SE Style U http://www.us.all.biz/g209/ XHHW-2 conductors are phase identified. One insulated conductor has a single longitudinal red stripe. One insulated conductor is black. The bare conductor strands are helically wound about the two paralleled insulated conductors. A glass-reinforced tape is applied over the conductors. A polyvinyl chloride (PVC) jacket, free of the heavy metals lead and cadmium, is extruded over the subassembly.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g209/ Cable, STABILOY®, Type SE Style R http://www.us.all.biz/g211/ Alcan Type SE Style R three conductor insulated, round-type Service Entrance Cable is designed for above-ground service entrance use, as well as interior wiring. The cable meets the requirements of Underwriters Laboratories Inc., Standard #854 and is approved for use in accordance with the recommendations of the National Electrical Code as Type SE. STABILOY® alloy conductor is recognized by ASTM in Standards B 800 and B 801. XHHW-2 conductors are phase identified. One insulated conductor has a single longitudinal red stripe. One insulated conductor is total surface painted white. One insulated conductor is black. If provided, a fourth insulated conductor has a single longitudinal blue stripe. The conductors are twisted together and a glass-reinforced tape is applied over the twisted conductors. A polyvinyl chloride (PVC) jacket, free of the heavy metals lead and cadmium, is extruded over the subassembly.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g211/ Building wire, Type XHHW-2, STABILOY® http://www.us.all.biz/g213/ Alcan Type XHHW-2 building wire is designed for general-purpose wiring in residential, commercial and industrial buildings. It meets the requirements of Underwriters Laboratories Inc., Standard #44 for Type XHHW-2 with a maximum operating temperature of 90° C in wet and dry locations. Rated at 600 volts, the cable is approved for use in accordance with the recommendations of the National Electrical Code. STABILOY® alloy conductor is recognized by ASTM.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g213/ Cable, STABILOY®, Type MC http://www.us.all.biz/g215/ Alcan Type MC Cable is designed for above-ground application. The cable is also available with a jacket over the armor, listed for direct burial, for application in cable tray and for sunlight resistance. STABILOY® MC meets the requirements of UL Standard #1569, Metal-Clad Cables. Insulated conductors within the cable meet the requirements of UL-44, Type XHHW-2. STABILOY® MC Cable is approved for use in accordance with applicable portions of the National Electrical Code. STABILOY® alloy conductor is recognized by ASTM in Standards B800 and B801.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g215/ Cable, STABILOY® NUAL® TECK90 1000V http://www.us.all.biz/g217/ TECK90 cable is a rugged, durable cable of versatile construction proven through many years of service in mines and major resource industries such as the pulp and paper, petrochemical and metal industries. The excellent inherent properties of TECK90 cable materials and construction ensure its continuous service, even when exposed to many forms of environmental degradation and attack. TECK90 is a flexible, interlocked aluminum armoured cable having an inner PVC jacket over insulated STABILOY® NUAL® RW90 conductors as well as outer PVC jacket over the armour. In Canada, the cable is approved for use in accordance with the recommendations of the Canadian Electrical Code as Type TECK90. In the US, for similar installations, the cable may be approved, where required, for use in accordance with Section 90-4 of the National Electrical Code by the authority having jurisdiction. TECK90 is CSA-approved for use in Class I, II, & III hazardous locations, Division I.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g217/ Cable, USE-2/RHH/RHW-2, STABILOY® http://www.us.all.biz/g219/ The cable has a maximum operating temperature of 90° C in dry and wet locations. Rated at 600 volts, the cable is sunlight resistant and is approved for use in accordance with the recommendations of the National Electrical Code in raceways and underground installations. STABILOY® alloy conductor is recognized by ASTM in Standards B800 and B801.]]> Fri, 29 Dec 2006 00:00:00 +0200 http://www.us.all.biz/g219/